Authorised Agent in Egypt — Delivery to all governorates
Companies we represent All companies
NOVOVENT F400 · 120 min

Smoke extract roof fan

CF / CF S / CF HT

Centrifugal roof fan for use outside the risk zone; motor isolated from extracted gases; weatherproof.

EN 12101-3 · F400 (120 min) · cert. 0370-CPR-1551
F400: the fan runs in 400 °C smoke for 120 minutes per EN 12101-3, the European standard for smoke and heat exhaust fans.

CF / CF S / CF HT — Roof Smoke Extraction Fans
models82
Airflow range856 – 26,170 m³/h
SpecificationØ 250–800 mm; up to 26,170 m³/h; motors up to 3 kW; 82 current models

Models

CF 25/6M
Airflow
856 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
35 dB(A)
Fire rating
—
CF 25/6T
Airflow
856 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
35 dB(A)
Fire rating
—
CF-S 25/6M
Airflow
856 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
35 dB(A)
Fire rating
—
CF-S 25/6T
Airflow
856 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
35 dB(A)
Fire rating
—
CF 25/4M
Airflow
980 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
44 dB(A)
Fire rating
—
CF 25/4T
Airflow
980 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
44 dB(A)
Fire rating
—
CF 25/4/8T
Airflow
980 m³/h
Diameter
250 mm
Power
0.6 kW
Noise
44 dB(A)
Fire rating
—
CF-S 25/4M
Airflow
980 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
44 dB(A)
Fire rating
—
CF-S 25/4T
Airflow
980 m³/h
Diameter
250 mm
Power
0.18 kW
Noise
44 dB(A)
Fire rating
—
CF-S 25/4/8T
Airflow
980 m³/h
Diameter
250 mm
Power
0.6 kW
Noise
44 dB(A)
Fire rating
—
CF 31/6M
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
41 dB(A)
Fire rating
—
CF 31/6T
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
41 dB(A)
Fire rating
—
CF-S 31/6M
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
41 dB(A)
Fire rating
—
CF-S 31/6T
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
41 dB(A)
Fire rating
—
CF 31/6T HT
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.55 kW
Noise
41 dB(A)
Fire rating
—
CF 31/6T HT FC6031T
Airflow
1,391 m³/h
Diameter
315 mm
Power
0.55 kW
Noise
41 dB(A)
Fire rating
F400 · 120 min
CF 31/4M
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
56 dB(A)
Fire rating
—
CF 31/4T
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
56 dB(A)
Fire rating
—
CF 31/4/8T
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.6 kW
Noise
56 dB(A)
Fire rating
—
CF-S 31/4M
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
56 dB(A)
Fire rating
—
CF-S 31/4T
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.18 kW
Noise
56 dB(A)
Fire rating
—
CF-S 31/4/8T
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.6 kW
Noise
56 dB(A)
Fire rating
—
CF 31/4T HT
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.55 kW
Noise
56 dB(A)
Fire rating
—
CF 31/4T HT FC4031T
Airflow
2,200 m³/h
Diameter
315 mm
Power
0.55 kW
Noise
56 dB(A)
Fire rating
F400 · 120 min
CF 35/6M
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.18 kW
Noise
45 dB(A)
Fire rating
—
CF 35/6T
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.18 kW
Noise
45 dB(A)
Fire rating
—
CF-S 35/6M
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.18 kW
Noise
45 dB(A)
Fire rating
—
CF-S 35/6T
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.18 kW
Noise
45 dB(A)
Fire rating
—
CF 35/6T HT
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.55 kW
Noise
45 dB(A)
Fire rating
—
CF 35/6T HT FC6035T
Airflow
2,487 m³/h
Diameter
355 mm
Power
0.55 kW
Noise
45 dB(A)
Fire rating
F400 · 120 min
CF 35/4M
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.37 kW
Noise
56 dB(A)
Fire rating
—
CF 35/4T
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.37 kW
Noise
56 dB(A)
Fire rating
—
CF 35/4/8T
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.6 kW
Noise
56 dB(A)
Fire rating
—
CF-S 35/4M
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.37 kW
Noise
56 dB(A)
Fire rating
—
CF-S 35/4T
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.37 kW
Noise
56 dB(A)
Fire rating
—
CF-S 35/4/8T
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.6 kW
Noise
56 dB(A)
Fire rating
—
CF 35/4T HT
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.55 kW
Noise
56 dB(A)
Fire rating
—
CF 35/4T HT FC4035T
Airflow
3,025 m³/h
Diameter
355 mm
Power
0.55 kW
Noise
56 dB(A)
Fire rating
F400 · 120 min
CF 40/6T
Airflow
3,500 m³/h
Diameter
400 mm
Power
0.18 kW
Noise
48 dB(A)
Fire rating
—
CF-S 40/6T
Airflow
3,500 m³/h
Diameter
400 mm
Power
0.18 kW
Noise
48 dB(A)
Fire rating
—
CF 40/6T HT
Airflow
3,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
48 dB(A)
Fire rating
—
CF 40/6T HT FC6040T
Airflow
3,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
48 dB(A)
Fire rating
F400 · 120 min
CF 45/6T
Airflow
3,900 m³/h
Diameter
450 mm
Power
0.37 kW
Noise
54 dB(A)
Fire rating
—
CF-S 45/6T
Airflow
3,900 m³/h
Diameter
450 mm
Power
0.37 kW
Noise
54 dB(A)
Fire rating
—
CF 45/6T HT
Airflow
3,900 m³/h
Diameter
450 mm
Power
0.55 kW
Noise
54 dB(A)
Fire rating
—
CF 45/6T HT FC6045T
Airflow
3,900 m³/h
Diameter
450 mm
Power
0.55 kW
Noise
54 dB(A)
Fire rating
F400 · 120 min
CF 40/4M
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
—
CF 40/4T
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
—
CF 40/4/8T
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.6 kW
Noise
58 dB(A)
Fire rating
—
CF-S 40/4M
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
—
CF-S 40/4T
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
—
CF-S 40/4/8T
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.6 kW
Noise
58 dB(A)
Fire rating
—
CF 40/4T HT
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
—
CF 40/4T HT FC4040T
Airflow
4,500 m³/h
Diameter
400 mm
Power
0.55 kW
Noise
58 dB(A)
Fire rating
F400 · 120 min
CF 35/2T
Airflow
5,500 m³/h
Diameter
355 mm
Power
1.5 kW
Noise
56 dB(A)
Fire rating
—
CF-S 35/2T
Airflow
5,500 m³/h
Diameter
355 mm
Power
1.5 kW
Noise
56 dB(A)
Fire rating
—
CF 45/4M
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF 45/4T
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF 45/4/8T
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.2 kW
Noise
62 dB(A)
Fire rating
—
CF-S 45/4M
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF-S 45/4T
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF-S 45/4/8T
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.2 kW
Noise
62 dB(A)
Fire rating
—
CF 45/4T HT
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
65 dB(A)
Fire rating
—
CF 45/4T HT FC4045T
Airflow
5,820 m³/h
Diameter
450 mm
Power
1.1 kW
Noise
65 dB(A)
Fire rating
F400 · 120 min
CF 56/6T HT FC6056T
Airflow
7,519 m³/h
Diameter
560 mm
Power
0.55 kW
Noise
59 dB(A)
Fire rating
F400 · 120 min
CF 56/6T
Airflow
8,016 m³/h
Diameter
560 mm
Power
0.55 kW
Noise
59 dB(A)
Fire rating
—
CF-S 56/6T
Airflow
8,016 m³/h
Diameter
560 mm
Power
0.55 kW
Noise
59 dB(A)
Fire rating
—
CF 56/6T HT
Airflow
8,016 m³/h
Diameter
560 mm
Power
0.55 kW
Noise
59 dB(A)
Fire rating
—
CF 56/4T
Airflow
11,278 m³/h
Diameter
560 mm
Power
2.2 kW
Noise
68 dB(A)
Fire rating
—
CF-S 56/4T
Airflow
11,278 m³/h
Diameter
560 mm
Power
2.2 kW
Noise
68 dB(A)
Fire rating
—
CF 63/6T HT FC6063T
Airflow
12,097 m³/h
Diameter
630 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
F400 · 120 min
CF 63/6T
Airflow
12,500 m³/h
Diameter
630 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF-S 63/6T
Airflow
12,500 m³/h
Diameter
630 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF 63/6T HT
Airflow
12,500 m³/h
Diameter
630 mm
Power
1.1 kW
Noise
62 dB(A)
Fire rating
—
CF 71/6T HT FC6071T
Airflow
17,835 m³/h
Diameter
710 mm
Power
1.5 kW
Noise
65 dB(A)
Fire rating
F400 · 120 min
CF 71/6T
Airflow
18,500 m³/h
Diameter
710 mm
Power
1.5 kW
Noise
65 dB(A)
Fire rating
—
CF-S 71/6T
Airflow
18,500 m³/h
Diameter
710 mm
Power
1.5 kW
Noise
65 dB(A)
Fire rating
—
CF 71/6T HT
Airflow
18,500 m³/h
Diameter
710 mm
Power
1.5 kW
Noise
65 dB(A)
Fire rating
—
CF 80/6T HT FC6080T
Airflow
25,170 m³/h
Diameter
800 mm
Power
3 kW
Noise
69 dB(A)
Fire rating
F400 · 120 min
CF 80/6T
Airflow
26,170 m³/h
Diameter
800 mm
Power
3 kW
Noise
69 dB(A)
Fire rating
—
CF-S 80/6T
Airflow
26,170 m³/h
Diameter
800 mm
Power
3 kW
Noise
69 dB(A)
Fire rating
—
CF 80/6T HT
Airflow
26,170 m³/h
Diameter
800 mm
Power
3 kW
Noise
69 dB(A)
Fire rating
—

Typical applications

Data per the official NOVOVENT catalogue. Maximum free-air values; final selection at the duty point is confirmed by an IMETCO engineer.

WhatsApp us View request